Vmware

5V0-22.21 practice test

Practice with 15 free Testara sample questions, or choose paid access to the full 57-question bank.

Provider
Vmware
Question bank
57
Free sample
15 questions
Publisher
Testara

About this practice material

This page covers Testara's practice question bank for 5V0-22.21, a certification listed under Vmware. Questions use original, exam-style scenarios and are not questions from the official certification exam.

Testara is an independent practice platform and is not affiliated with, endorsed by, or authorized by Vmware. The certification credential is issued by Vmware, not Testara. Certification and provider names belong to their respective owners.

Start practicing

The guest demo does not save an attempt. Sign in before buying access.

Try 15 questions free

Available without signing in

Free sample questions

These 15 questions and their explanations are server-rendered so you can inspect the material before opening the interactive demo.

  1. Question 1 · 1

    A vSAN administrator, who has a cluster that has both compute-only and vSAN ReadyNodes, recently received a request to deploy a new application with higher storage performance requirements than what are currently available. What are two ways the administrator can reconfigure the vSAN cluster to obtain this additional performance? (Choose two.)

    Choose all answers that apply.

    • Add additional hosts, with capacity devices only, and then stream the cache from the other hosts.
    • Add cache and capacity devices to the compute-only hosts.
    • Add additional cache and capacity devices to the existing data nodes.
    • Add additional compute-only hosts from the vSAN cluster.
    • Add to the existing disk groups two cache devices and the eight capacity devices.
  2. Question 2 · 1

    Which two conditions should be verified before removing an ESXi host from a vSAN cluster? (Choose two.)

    Choose all answers that apply.

    • Resyncs are running
    • Data evacuation is complete
    • Performance Service is disabled
    • Encryption is disabled
    • ESXi host is in maintenance mode
  3. Question 3 · 1

    In a 2-node vSAN cluster, one node has recovered from failure with FTT=1 and RAID-1 storage policy. Refer to the exhibit: What is the total VMDK storage consumed?

    Choose one answer.

    Question illustration 1
    • 150 GB
    • 100GB
    • 133GB
    • 200GB
  4. Question 4 · 1

    A vSAN administrator is implementing deduplication and compression on a vSAN all-flash cluster but wants the VMs to remain operational. The details are as follows: ✑ There are 4 nodes in the vSAN cluster. ✑ Existing VMs use a RAID-5 storage policy. Which action should the vSAN administrator take to meet this goal?

    Choose one answer.

    • Use explicit fault domains.
    • Enable TRIM/UNMAP.
    • Change the existing VM storage policy to RAID-6.
    • Use the Allow Reduced Redundancy option.
  5. Question 5 · 1

    A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task. What is the fastest approach?

    Choose one answer.

    • Use a Host Profile that was extracted from an existing host.
    • Clone the ESXi boot partition to all new hosts, since the hardware is identical.
    • Run vim-cmd to capture, and apply the configuration from an existing host.
    • Launch Quickstart to Add Hosts to a vSAN Cluster
  6. Question 6 · 1

    Which tool should be used to identify vSAN unassociated objects?

    Choose one answer.

    • vSphere Host Client
    • vSphere CLI
    • vsantop
    • PowerCLI
  7. Question 7 · 1

    What are two purposes of a vSAN storage policy (Choose two.)

    Choose all answers that apply.

    • To determine vSAN encryption level
    • To enable TRIM/UNMAP
    • To define how the VM storage objects are provisioned
    • To guarantee the required level of service
    • To enable deduplication and compression
  8. Question 8 · 1

    A new host with local storage devices has been added to a vSAN cluster. Now, the administrator would like to increase the capacity of the vSAN datastore. What must be done to the new host to accomplish this goal?

    Choose one answer.

    • Configure a RAID set on the storage controller.
    • Create one or more disk groups.
    • Delete all existing partitions.
    • Perform a storage device rescan.
  9. Question 9 · 1

    The objects on a 4-node vSAN cluster are assigned a RAID-5 policy. A network outage occurs, causing host one to lose connectivity with the rest of the cluster. Seventy-five minutes have elapsed. What is the health state of the objects?

    Choose one answer.

    • Reduced availability with no rebuild
    • Non-availability related incompliance (non-compliance)
    • Reduced availability
    • Reduced availability with no rebuild - delay timer
    Read explanation

    Minimum number of hosts required for Raid 5: 2n+1. Reduced availability - active rebuild: The object has suffered a failure, but it was configured to be able to tolerate the failure. I/O continues to flow and the object is accessible. vSAN is actively working on re-protecting the object by rebuilding new components to bring the object back to compliance. Reduced availability with no rebuild: The object has suffered a failure, but VSAN was able to tolerate it. For example: I/O is flowing and the object is accessible. However, VSAN is not working on re-protecting the object. This is not due to the delay timer (reduced availability - no rebuild - delay timer) but due to other reasons. This could be because there are not enough resources in the cluster, or this could be because there were not enough resources in the past, or there was a failure to re-protect in the past and VSAN has yet to retry.

  10. Question 10 · 1

    Which two actions are recommended when adding a host to a vSAN cluster? (Choose two.)

    Choose all answers that apply.

    • Disable vSphere High Availability (HA).
    • Create uniformly-configured hosts.
    • Reference the VMware Compatibility Guide.
    • Disable vSphere Cluster Services (vCLS).
    • Disable vSAN performance service.
  11. Question 11 · 1

    An existing vSAN cluster has this specification: ✑ Four ESXi hosts with all flash configuration ✑ Each with two disk groups ✑ Each disk group with one cache device and four capacity devices ✑ There are five more device slots available The CTO would like to provision new applications, and these will need more capacity and performance. Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)

    Choose all answers that apply.

    • Adding faster cache devices
    • Adding one more disk group per host with the same configuration
    • Replacing all cache devices by a larger device
    • Adding an ESXi host with identical device configuration
    • Replacing all capacity devices by a larger device
  12. Question 12 · 1

    An administrator wants to check the vSAN cluster health during the maintenance window while vCenter Server is offline. What are two ways to complete this task? (Choose two.)

    Choose all answers that apply.

    • HCIBench
    • ESXi system logs on vSAN datastore
    • esxcli
    • vSphere Host Client
    • esxtop
  13. Question 13 · 1

    A vSAN administrator is troubleshooting poor performance of vSAN cluster while vCenter is not available. The vSAN administrator decides to use a command line tool to monitor real-time vSAN IOPS, throughput, and other metrics on ESXi host. Which command line tool should be used?

    Choose one answer.

    • vimtop
    • esxcli
    • esxcfg
    • vsantop
  14. Question 14 · 1

    A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources. Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)

    Choose all answers that apply.

    • RAID-5/FTT=1
    • vSAN stretched cluster
    • Specify fault domains
    • RAID-6/FTT=2
    • 2-node configuration
  15. Question 15 · 1

    Which Storage Policy Structure Rule is supported by vSAN Direct Datastore?

    Choose one answer.

    • Enable tag/capacity-based placement rules
    • Enable host-based rules
    • Enable rules for vSAN storage
    • Enable storage performance-based rules

Each purchase applies to this certification. Prices are one-time payments, not monthly subscriptions.

Starter

$29 USD one time

Full access to one certification's question bank in standard practice mode for 60 days.

  • Full question bank for one certification
  • 60 days of access
  • Standard practice mode
  • Question notes and community discussions
  • Attempt scores and answer review

Professional

$49 USD one time

Full access to one certification's question bank, custom test controls and advanced analytics for 60 days.

  • Custom test builder
  • Timers and question selection
  • Randomized question and answer order
  • Advanced performance and weak-question analytics
  • Priority customer support
Try 15 questions free